VK and TR GAS FRYERS W/Wo
KleenScreen PLUS
VK Series
TR Series
- NOTICE -
This Manual is prepared for the use of trained Vulcan Service
Technicians and should not be used by those not properly
qualified.
This manual is not intended to be all encompassing. If you have
not attended a Vulcan Service School for this product, you should
read, in its entirety, the repair procedure you wish to perform to
determine if you have the necessary tools, instruments and skills
required to perform the procedure. Procedures for which you do
not have the necessary tools, instruments and skills should be
performed by a trained Vulcan Service Technician.
The reproduction, transfer, sale or other use of this Manual,
without the express written consent of Vulcan, is prohibited.
This manual has been provided to you by ITW Food Equipment
Group LLC ("ITW FEG") without charge and remains the property
of ITW FEG, and by accepting this manual you agree that you will
return it to ITW FEG promptly upon its request for such return at
any time in the future.
SERVICE MANUAL
A product of Vulcan-Hart 3600 North Point Blvd Baltimore, MD 21222
F45474 (0413)
Vue de la page 0
1 2 3 4 5 6 ... 54 55

Résumé du contenu

Page 1 - SERVICE MANUAL

VK and TR GAS FRYERS W/WoKleenScreen PLUSVK SeriesTR Series- NOTICE -This Manual is prepared for the use of trained Vulcan ServiceTechnician

Page 2 - TABLE OF CONTENTS

ANALOG CONTROL Disconnect theelectrical power to the machine andfollow lockout / tagout procedures. Shut off the gas before servicing theunit.1. Open

Page 3

INTERFACE CONTROL - D and CSERIES Disconnect theelectrical power to the machine andfollow lockout / tagout procedures. Shut off the gas before servici

Page 4 - MODEL AND ML NUMBERS

2. Unplug temperature probe lead wire connector.Fig. 15NOTE: This picture shows the probes with the burnerremoved.3. Loosen compression nut and remov

Page 5 - SYSTEM: (KSP)

Fig. 18NOTE: This picture shows the probes with the burnerremoved.5. Slide high limit probe out of fry tank.Fig. 196. Reverse procedure to install an

Page 6 - CONTROL PANELS

Fig. 213. Unplug all connecters from power supply box andremove box from under fryer.4. Remove cover to access power supply boxcomponents.Fig. 22Fig.

Page 7 - SPECIFICATIONS

Fig. 244. Reverse procedure to install new relay.5. Reinstall power supply box and check operation.120 Volt Transformer1. Remove POWER SUPPLY BOX.2. N

Page 8

Fig. 264. Reverse the procedure to install newtransformer.5. Reinstall power supply box and check operation.Control Board1. Remove POWER SUPPLY BOX.2.

Page 9 - COVERS AND PANELS

Fig. 294. Remove bolts and remove burner from fryer.Fig. 305. Reverse procedure to reinstall burner.GAS VALVE Disconnect theelectrical power to the ma

Page 10 - ANALOG CONTROL

Fig. 314. Reverse procedure to install.BASKET LIFT MOTOR Disconnect theelectrical power to the machine andfollow lockout / tagout procedures.1. Remove

Page 11 - TEMPERATURE PROBE

BASKET LIFT CAM SWITCH Disconnect theelectrical power to the machine andfollow lockout / tagout procedures.1. Remove BASKET LIFT TUBE.2. Disconnect le

Page 12 - HIGH LIMIT THERMOSTAT

TABLE OF CONTENTSGENERAL ... 4INTRODUCTION ...

Page 13 - POWER SUPPLY BOX

Fig. 365. Reverse procedure to reinstall valve.FILTER HOSE SWITCH (KSP) Disconnect theelectrical power to the machine andfollow lockout / tagout proce

Page 14 - COMPONENTS BEFORE 12/1/12

Fig. 384. Disconnect electric connections to filter pumpmotor.5. Unbolt filter pump motor from fryer frame.6. Carefully remove filter pump assembly th

Page 15 - COMPONENTS AFTER 12/1/12

Fig. 406. Unplug drain valve interlock switch from wiringharness and remove switch from fryer.7. Reverse procedure to install and check for properoper

Page 16 - BURNER ASSEMBLY

Fig. 437. Remove fry tank bolt down bracket.Fig. 448. Remove fry tank cover plate.Fig. 45A. Cover plate is glued to tank and will have tobe pried off.

Page 17 - BASKET LIFT TUBE

SERVICE PROCEDURES AND ADJUSTMENTS Certain procedures in this section require electrical test or measurements whilepower is applied to the machine. Ex

Page 18 - BASKET LIFT MOTOR

TEMPERATURE (°F) RESISTANCE (Ω)77 90,000 - 110,000350 604 - 836415 1302 - 369460 2191 - 2331 High temperature alarm level for the cookingcontrols2 S

Page 19 - FILL SOLENOID VALVE (KSP)

Fig. 483. Remove the red flame sense wire.4. Place one Microamp meter lead on the red wire.5. Place the other meter lead on the terminal youremoved th

Page 20 - (KLEENSCREEN FRYERS ONLY)

flame has not been detected within 5 seconds red lighton ignition module will blink.Fig. 50"A" style controller: Red light will blink and bl

Page 21 - SWITCH (DVI)

Fig. 51SOLID STATE CONTROLOperationUse service information in this section when servicinga fryer with a solid state control. Refer to instructionmanua

Page 22 - FRY TANK

Control ProgrammingPROGRAMITEMKEY SEQUENCEDISPLAY 1Low CookTemp LockoutPress left basket to increase or right basket to decrease cooking cycle lockout

Page 23

MODULATING GAS VALVE ADJUSTMENTS ... 27BASKET LIFT ARM ADJUSTMENT ...

Page 24 - TEMPERATURE PROBE TEST

Control ProgrammingPROGRAMITEMKEY SEQUENCEDISPLAY 1NOTES1 Default value shown in bold type.2 Temperature will change in one degree increments, acce

Page 25 - PRIOR TO 12/1/12

ALARMS DESCRIPTIONDRAIN VALVE INTERLOCK(DVI) Filtering System FryerBatteries (Filter Key)When drain valve is opened, the DVI switch contacts open, and

Page 26 - ELECTRONIC IGNITION CONTROL

Fig. 54NOTE: The controls heat demand output signal is offand the heat/ignition status input signal is ignored ifthe fryer is in cook mode or idling.

Page 27 - BASKET LIFT ARM ADJUSTMENT

Fig. 573) To adjust the selected screen:a. BACKLIGHT - Press toggle key toturn display backlight ON or OFF.b. PIXEL MODE - Press product keynumber 1 t

Page 28 - SOLID STATE CONTROL

SERVICESETTINGSKEY SEQUENCEDISPLAYITEMFLASHES1DESCRIPTION5Temp OffsetPress 5 to change offset temperature.Press toggle key to change offset value to (

Page 29

SERVICESETTINGSKEY SEQUENCEDISPLAYITEMFLASHES1DESCRIPTION6.) DisplayPress 6 to adjust the left and right display screensettings. Refer to LCD display

Page 30

DISPLAY, LED AND KEYPAD TEST- COMPUTER CONTROL1. Press and hold the 5 key while turning power onto Initiate test. Release the 5 key during displayof s

Page 31 - COMPUTER CONTROL

Fig. 59NOTE: For fryers built after 12/1/12, the fire timersare replaced by a Ignition/Blower control board. Thehigh and low fire time settings are p

Page 32

Fig. 62If the spark igniter rod is not adjusted correctly the gascould build up in the burner assembly and cause adelayed ignition of the burner. The

Page 33

Fig. 65VK and TR GAS FRYERS W/Wo KleenScreen PLUS - SERVICE PROCEDURES AND ADJUSTMENTSPage 39 of 55 F45474 (0413)

Page 34

GENERALINTRODUCTION This service manual covers the specific service information related to the models listed in the chart below. The VKand TR series g

Page 35

ELECTRICAL OPERATIONCOMPONENT FUNCTION - FRYER CONTROLSIgnitor/ Ground (After12/1/12) ...Ignites the gas burner and senses the presence of

Page 36 - HIGH/LOW FIRE TIMER SETTING

COMPONENT FUNCTION - KLEENSCREEN FILTER CONTROLSFill Solenoid Valve ... When energized by filter key, the solenoid valve opens to allow the flow of

Page 37 - SPARK GAP SETTING BEFORE

Fig. 69Fig. 70SEQUENCE OF OPERATION - ASERIES - AFTER 12/1/12Refer to the schematic diagrams for Analog Controloperation.NOTE: If the Solid/ Liquid s

Page 38 - SPARK GAP SETTING AFTER

SEQUENCE OF OPERATION D ANDC SERIESRefer to SCHEMATIC AI3495 for Cooking Controloperation.NOTE: If using solid shortening, the control should beprogr

Page 39 - Page 39 of 55 F45474 (0413)

12. If shortening is allowed to cool over a long periodof time, burner will operate on low heat tomaintain shortening temperature near operatingtemper

Page 40 - ELECTRICAL OPERATION

SCHEMATIC DIAGRAMSAnalog Controls - No OptionsVK and TR GAS FRYERS W/Wo KleenScreen PLUS - ELECTRICAL OPERATIONPage 45 of 55 F45474 (0413)

Page 41 - COMPONENT LOCATION

Analog Controls - KleenscreenVK and TR GAS FRYERS W/Wo KleenScreen PLUS - ELECTRICAL OPERATIONF45474 (0413) Page 46 of 55

Page 42 - SERIES - AFTER 12/1/12

Solid State or Computer Control - No OptionsVK and TR GAS FRYERS W/Wo KleenScreen PLUS - ELECTRICAL OPERATIONPage 47 of 55 F45474 (0413)

Page 43 - C SERIES

Solid State of Computer Control - KleenscreenVK and TR GAS FRYERS W/Wo KleenScreen PLUS - ELECTRICAL OPERATIONF45474 (0413) Page 48 of 55

Page 44

WIRING DIAGRAMSVK Fryer (C and D Models)VK and TR GAS FRYERS W/Wo KleenScreen PLUS - ELECTRICAL OPERATIONPage 49 of 55 F45474 (0413)

Page 45 - SCHEMATIC DIAGRAMS

MODEL ML # MODEL ML # MODEL ML #1TR45CF 136957 1TR65CF 136970 2TR85CF 1369832TR45CF 136958 2TR65CF 136971 3TR85CF 1369844TR65AF 136985 4TR65DF 136986

Page 46 - F45474 (0413) Page 46 of 55

Power Supply Box (Before 12/1/12) - VK Fryer with basket lifts and KleenscreenVK and TR GAS FRYERS W/Wo KleenScreen PLUS - ELECTRICAL OPERATIONF45474

Page 47 - Page 47 of 55 F45474 (0413)

Power Supply Box (Before 12/1/12) - VK Fryer without basket lifts and KleenscreenVK and TR GAS FRYERS W/Wo KleenScreen PLUS - ELECTRICAL OPERATIONPage

Page 48 - F45474 (0413) Page 48 of 55

VK Fryers with Electronic Ignition and Analog Control and KleenscreenVK and TR GAS FRYERS W/Wo KleenScreen PLUS - ELECTRICAL OPERATIONF45474 (0413) Pa

Page 49 - WIRING DIAGRAMS

VK Fryers with Electronic Ignition and Analog ControlVK/TR D & C Fryer Wiring DiagramVK/TR Analog Control W/ Kleenscreen Fryer WiringDiagramVK/TR

Page 50 - F45474 (0413) Page 50 of 55

TROUBLESHOOTINGTROUBLESHOOTING ALL MODELSSYMPTOMS POSSIBLE CAUSESIgnition lockout, continuous loud beep1. Harness connection to gas valve.2. Gas valve

Page 51 - Page 51 of 55 F45474 (0413)

ALL MODELSSYMPTOMS POSSIBLE CAUSESExcessive heat1. Incorrect temperature offset selected.2. Set temperature exceeding 400°F.3. Temperature probe malfu

Page 52 - F45474 (0413) Page 52 of 55

This system is designed to provide a through and easymethod to filter the shortening. Some of the benefitsinclude:• Self-contained system eliminating

Page 53

SOLID STATE CONTROLCOMPUTER CONTROLUSB PortINSTALLATIONRefer to the Instruction Manual for detailed installationinstructions.OPERATIONRefer to the Ins

Page 54 - TROUBLESHOOTING

unit). On fryers built after 12/1/12 an incoming gaspressure regulator is installed on the fryer.VKINPUT BTU RATINGVK SERIES BTU/HR/SECTIONVK45A, VK45

Page 55

REMOVAL AND REPLACEMENT OF PARTSCOVERS AND PANELS Disconnect theelectrical power to the machine andfollow lockout / tagout procedures. Shut off the ga