4. Remove bolts and remove burner from fryer.
Fig. 30
5. Reverse procedure to reinstall burner.
GAS VALVE
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
The gas valve is considered part of the burner
assembly. If the gas valve fails and needs to be
replaced, you must order a complete blower/gas valve
assembly (burner). The reason for this is every blower/
gas valve assembly (burner) is set up at the factory to
operate at the most efficient level possible. This set up
procedure cannot be duplicated in the field. If you feel
that the gas valve is not set up correctly or not
operating correctly, call product service and they will
help solve the problem.
BASKET LIFT TUBE
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1. Remove
BASKET LIFT COVERS.
2. Remove nut securing lift bar to lift tube.
3. Remove screws securing lift tube bracket to fryer
then remove bracket and lift tube.
VK and TR GAS FRYERS W/Wo KleenScreen PLUS - REMOVAL AND REPLACEMENT OF PARTS
Page 17 of 55 F45474 (0413)