TROUBLESHOOTING
TROUBLESHOOTING
ALL MODELS
SYMPTOMS POSSIBLE CAUSES
Ignition lockout, continuous loud beep
1. Harness connection to gas valve.
2. Gas valve or gas pressure.
3. Air filter.
4. All harness connections.
5. Electrode.
6. Drain valve switch open or switch malfunction.
7. Interconnecting wiring malfunction.
8. Ignition module malfunction.
9. High limit or thermostat open.
10. Vent hose closed off or restricted.
Initial beep then shut off
1. Grounding status.
2. Check electrode.
No spark no blower
1. Harness connections (check for flashing light in A
control).
2. Probe lead wires.
3. Open probe.
4. Controller.
5. Open fuse on ignition/blower control board
"Puffing" during initial start up
1. Air Filter dirty.
2. Incorrect gas pressure.
3. Vent hose closed off or restricted.
4. Cracked electrode.
5. Electrode gap exceeding 3/16".
Burner lights but will not maintain flame
1. Igniter/flame sense misaligned.
2. Insufficient gas pressure.
3. Incorrect polarity from transformer to ignition
module.
VK and TR GAS FRYERS W/Wo KleenScreen PLUS - TROUBLESHOOTING
F45474 (0413) Page 54 of 55