SOLID STATE CONTROL
COMPUTER CONTROL
USB Port
INSTALLATION
Refer to the Instruction Manual for detailed installation
instructions.
OPERATION
Refer to the Instruction Manual for specific operating
instructions.
CLEANING
Refer to the Instruction Manual for specific cleaning
instructions.
TOOLS
STANDARD
Standard set of hand tools.
VOM with A.C. current tester (any quality VOM
with a sensitivity of at least 20,000 ohms per volt
can be used).
SPECIAL
Temperature tester (thermocouple type)
Manometer.
Combustion Analyzer
Set of Metric Hex Wrenches (must include a 2
mm wrench)
Set of jewelers screwdrivers
Field service grounding kit P/N TL- 84919.
Burndy pin extraction tool RX2025 GE1; Newark
Electronics Catalog Number 16F6666. Used for
removing pin terminals on Burndy connectors.
Thumb Drive (part number 443444) (Customer to
supply program for uploading menu items)
SPECIFICATIONS
ELECTRICAL:
120VAC supply.
Filter motor/pump
Basket lift motors
Transformer
24VAC transformer
Fryer controls
Basket lift relays
Filter relay
MANIFOLD GAS PRESSURES (per fryer section)
Natural - 0.08" W.C.
Propane - 0.08" W.C.
BUILDING SUPPLY PRESSURE (MAX)
Natural Single Fryer - 6" W.C.
Natural Battery Fryer - 8" W.C.
Propane Single and Battery Fryers - 11" W.C.
NOTE: Natural and propane gases listed above are
maximum supply pressures. On fryers built before
12/1/12 a separate gas regulator must be used for
pressures exceeding maximum (not supplied with
VK and TR GAS FRYERS W/Wo KleenScreen PLUS - GENERAL
Page 7 of 55 F45474 (0413)