SERVICE PROCEDURES AND ADJUSTMENTS
Certain procedures in this section require electrical test or measurements while
power is applied to the machine. Exercise extreme caution at all times and follow Arc Flash
procedures. If test points are not easily accessible, disconnect power and follow Lockout/Tagout
procedures, attach test equipment and reapply power to test.
ELECTRIC CONNECTIONS
The VK series fryers are supplied with a 120Volt cord
and three prong plug. If local electrical codes require
that these fryers be plugged into a Ground Fault
Interrupter or GFI. You must use GFI part number
913053. Other GFI outlets may not have the correct
tolerance for the spark to ground ignition system
employed with the VK series fryers.
HARMONIC TONE
Harmonic Tone (hum) at First Start
At first start, fryer will begin heating in low fire. There
will be a harmonic tone that is NORMAL to hear. As
fryer continues to heat, harmonic tone will dissipate
and become less noticeable. When fryer reaches
135°F (end of melt cycle), fryer will heat on high fire
and blower speed will increase.
TEMPERATURE PROBE FAULT
CODES
The temperature probe is used for both the solid state
control and the computer control. The probe is an RTD
(resistance temperature detector) of the thermistor
type. As temperature increases the resistance value
decreases.
Probe Fault
If a temperature probe fault or high temperature
condition occurs, a fault message will be displayed
and the electronic alarm will sound continuously. The
heat demand and basket lift outputs are de-activated.
If a cooking cycle is in process (timer active), it will be
cancelled and the key pad disabled.
This will continue until the fault clears, power is cycled
or problem resolved.
CONTROL TYPE FAULT
SOLID STATE
An open will display Prob and
a short or high temperature
condition will display HI.
CONTROL TYPE FAULT
COMPUTER
An open will display PROBE
OPEN and a short or high
temperature condition will
display PROBE SHORT.
TEMPERATURE PROBE TEST
To Check:
1. Turn power switch off.
2. Disconnect the temperature probe plug.
Fig. 47
3. Test the probe using a VOM to measure
resistance. Connect the meter leads to the wires
removed in step 2.
A. If the measured resistance values are within
the allowable range, the probe is functioning
properly. Reverse procedure to install.
B. If the measured resistance values are
outside the allowable range, install a
replacement probe and check for proper
operation.
VK and TR GAS FRYERS W/Wo KleenScreen PLUS - SERVICE PROCEDURES AND ADJUSTMENTS
F45474 (0413) Page 24 of 55